SBCRI is very careful to maintain the confidentiality of our clients' proprietary information and testing. SBCRI's doors are locked at all times. Qualtim staff must get clearance from Qualtim's President, Vice President or Director of R&D and Industry Projects before entering or taking any visitors into the SBCRI testing facility.

Standard Testing Approach


Let’s assume that you desire to understand the performance of a new shear wall. Our facility can take you through product development in a common sense yet sophisticated manner assessing in situ performance as follows:

Step 1 Your shear wall is tested vertically to traditional industry standards monotonically (ASTM E 564) or cyclically (ASTM E 2126).
Step 2 Your shear wall is then placed in a real 16-foot wide x 30-foot long structure that includes 4 walls and a roof. (See figures 1 and 2.)
Step 3 Your shear wall is tested monotonically and/or cyclically or both, parallel with and perpendicular to the roof trusses.
Step 4 Your shear wall’s real life performance is compared to the ASTM performance. Calibration is performed and design values are created that have relevance to real-world applications.

Figure 1 Figure 2
Figure 1 Figure 2

Now, your future product development and comparative performance becomes far easier!